No Spec: Geometric Arc; Inc Value In 2Nd Block (Geomt); No Linear Move Command (Geomt); Illegal Address (Geomt) - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P391

No spec: Geometric arc

Details
There are no geometric IB specifications.
Remedy
Check the specifications.
P392
Angle < 1 degree (GEOMT)
Details
The angular difference between the geometric line and line is 1° or less.
Remedy
Correct the geometric angle.
P393

Inc value in 2nd block (GEOMT)

Details
The second geometric block has a command with an incremental value.
Remedy
Issue a command with an absolute value in the second geometric block.
P394

No linear move command (GEOMT)

Details
The second geometric block contains no linear command.
Remedy
Issue the G01 command.
P395

Illegal address (GEOMT)

Details
The geometric format is invalid.
Remedy
Correct the program.
P396
Plane selected in GEOMT ctrl
Details
A plane switching command was issued during geometric command processing.
Remedy
Complete the plane switching command before geometric command processing.
P397
Arc error (GEOMT)
Details
In geometric IB, the circular arc end point does not contact or cross the next block start point.
Remedy
Correct the geometric circular arc command and the preceding and following commands.
P398
No spec: Geometric1B
Details
A geometric command was issued though the geometric IB specifications are not provided.
Remedy
Check the specifications.
IB-1501279-H
144

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents