M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P391
No spec: Geometric arc
Details
There are no geometric IB specifications.
Remedy
Check the specifications.
P392
Angle < 1 degree (GEOMT)
Details
The angular difference between the geometric line and line is 1° or less.
Remedy
Correct the geometric angle.
P393
Inc value in 2nd block (GEOMT)
Details
The second geometric block has a command with an incremental value.
Remedy
Issue a command with an absolute value in the second geometric block.
P394
No linear move command (GEOMT)
Details
The second geometric block contains no linear command.
Remedy
Issue the G01 command.
P395
Illegal address (GEOMT)
Details
The geometric format is invalid.
Remedy
Correct the program.
P396
Plane selected in GEOMT ctrl
Details
A plane switching command was issued during geometric command processing.
Remedy
Complete the plane switching command before geometric command processing.
P397
Arc error (GEOMT)
Details
In geometric IB, the circular arc end point does not contact or cross the next block start point.
Remedy
Correct the geometric circular arc command and the preceding and following commands.
P398
No spec: Geometric1B
Details
A geometric command was issued though the geometric IB specifications are not provided.
Remedy
Check the specifications.