Mitsubishi Electric M800 Series Manual page 432

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1267
ext03
bit0: G code type
Select the high-speed high-accuracy G code type.
0: Conventional format (G61.1)
1: MITSUBISHI CNC special format (G08P1)
(PR)
#1268
ext04
bit2: Enable synchronous tapping per minute
Select whether to enable feed per minute with the F command of synchronous tapping cycle.
0: Disable (Command in pitch regardless of "G group 5" modal)
1: Enable (Follow "G group 5" modal)
bit4:
Select whether to enable address K to be used for specifying the repetition count in G76/G87 command.
0: Disable
1: Enable
When 1 is set in this parameter with #1271ext07/bit1 (Specifying repetition count with address K) set to 1,
the address K given to G76/G87 is treated as the number of repetitions.
(PR)
#1269
ext05
bit0: Inverse tangent (ATAN) command format
Select the command format of ATAN operation.
0: Format 1: Either the ratio of two sides or the whole expression is enclosed in square brackets "[ ]".
ATAN[#k] or ATAN[#j/#k]
1: Format 2: Two sides are enclosed in "[ ]" respectively and also divided by a slash "/".
ATAN[#j]/[#k]
bit1: Range of inverse tangent (ATAN) calculation result
Select the range of calculation result for inverse tangent (ATAN) to be applied when Format 2 is selected for
inverse tangent (ATAN) command (when #1269/bit0=1).
0: -180 to 180 deg
1: 0 to 360 deg
415