M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#8955

Init axis pair

[M8]
Select the default coordinate axis combination to be displayed on the [Surface detail] screen of R-Navi.
0,1: Z/X
2: Z/Y
3: X/Y
[C80]
Not used.
(PR)
#8956

User key type

[M8]
Select the definition type of the user-defined keys.
There are two user-defined keys.
Type 1:
It is the same as the conventional specification. A line feed between "[ ]" is not dealt as ";".
It is dealt as an upper case/lower case letter depending on the CapsLock status.
A symbolic character may be converted into a specific character.
Type 2:
A line break inside square brackets "[ ]" is dealt as ";".
Regardless of the CapsLock status, the defined character is input.
A symbolic character is also input as defined.
0 : Type 1 (Conventional specification)
1 : Type 2
[C80]
Not used.
(PR)
#8957

T meas (L)-Simple

Select the operation mode of the manual tool length measurement 1 for L system.
0: Normal operation mode (Conventional specification)
Select an axis to measure using the cursor position.
1: Simple operation mode
Select an axis to measure using an axis address key or menu.
More than one axis can be selected.
#8958

SP on 5th part sys

Select which spindle to display in the 5th part system window for the 2-, 3- or 4-part system simultaneous
display.
(Note 1) If you select "00" for the 2-, 3- or 4-part system simultaneous display, the default display is used (1st
spindle on the upper side and 2nd spindle on the lower side).
(Note 2) If you set the same number as, or a greater number than the setting of "#1039 spinno", or if the high-
or low-order setting is "0", the 1st spindle is displayed.
(Note 3) If you set the low-order to F, the screen shows the actual rotation speed, command speed and load
meter of the high-order spindle.
Note that for the 4-counter display in 4-part system simultaneous display, even if the low-order is not
F, the screen shows the actual rotation speed, command speed and load meter of the high-order
and low-order spindles.
(Note 4) [M8] 3- or 4-part system simultaneous display is enabled for a 15- or 19-type display unit only.
[C80] 3- or 4-part system simultaneous display is not available.
---Setting range---
High-order(Select an upper side spindle.): 0 to 8
Low-order(Select a lower side spindle.): 0 to 8, F