1 Operation Errors (M)
M01
In synchronous correction mode
Details
The synchronous correction mode switch was pressed in non-handle mode.
Remedy
Select the handle or manual arbitrary feed mode.
Turn OFF the correction mode switch.
M01
No synchronous control option
Details
The synchronous control operation method was set (with R2589) while no synchronous control option was pro-
vided.
Remedy
Set "0" for "synchronous control operation method".
M01
Computer link B not possible
Details
Cycle start was attempted before resetting was completed.
Computer link B operation was attempted at the 2nd or further part system in a multi-part system.
Remedy
Perform the cycle start after resetting has been completed.
Set "#8109 HOST LINK" to "0" and then set to "1" before performing the cycle start.
Computer link B operation cannot be performed at the 2nd or further part system in a multi-part system.
M01
X/Z axes simultaneous prohibit
Details
The basic axis corresponding to the inclined axis was started simultaneously in the manual mode while the in-
clined axis control was valid.
Remedy
Turn the inclined axis and basic axis start OFF for both axes. (This is also applied for manual/automatic
simultaneous start.)
Disable the basic axis compensation, or command it to axes one by one.
M01
Program restart machine lock
Details
Machine lock was applied on the return axis being manually returned to the restart position.
Remedy
Cancel the machine lock and resume the operation.
M01
Rot axis parameter error
Details
Orthogonal coordinate axis name does not exist.
Rotary axis name does not exist.
A duplicate name is used for the designated orthogonal coordinate axis.
The number of axes that were selected to change tool length compensation along the tool axis amount exceeds
the maximum number of axes.
The designated orthogonal coordinate axis name is the same as the rotary axis name.
Remedy
Correct the rotary axis configuration parameters.
M01
Restart pos return incomplete
Details
Cycle start was performed with an axis whose return to the restart position was not complete.
Remedy
Perform restart position return manually.
Validate the parameter "#1302 AutoRP" (Automatic return by program restart), then execute cycle start.