14 Multi CPU Errors (A) [C80]
A01
Inter-module synch signal error
Details
An inter-module synchronization error has been detected.
Remedy
Take measures to reduce noise.
Reset the CPU module, and run it again. If the same error code is displayed again, the possible cause is
a hardware failure of the CPU module, base unit, extension cable, or module (I/O module or intelligent func-
tion module) connected. Please consult your local Mitsubishi representative.
A01

Multiple CPU synch signal error

Details
An execution interval error of the synchronization interrupt program has been detected.
A multiple CPU synchronization error has been detected.
Remedy
Take measures to reduce noise.
Reset the CPU module, and run it again. If the same error code is displayed again, the possible cause is
a hardware failure of the CPU module or base unit. Please consult your local Mitsubishi representative.
A01
Multiple CPU synch signal error
Details
A multiple CPU synchronization error has been detected.
Remedy
Take measures to reduce noise.
Reset the CPU module, and run it again. If the same error code is displayed again, the possible cause is
a hardware failure of the CPU module or base unit. Please consult your local Mitsubishi representative.
A01

Boot function execution error

Details
When the boot function was executed, the file format processing failed.
Remedy
Reset the CPU module, and execute the boot function again. If the same error code is displayed again,
the possible cause is a hardware failure of the CPU module. Please consult your local Mitsubishi represen-
tative.
A01
Boot function execution error
Details
When the boot function was executed, the file passwords did not match.
Remedy
Check and correct the file password settings of the transfer source and transfer destination files.
Delete the boot setting.
A01
Boot function execution error
Details
When the boot function was executed, the CPU built-in memory capacity was exceeded.
Remedy
Check and correct the boot setting.
Delete unnecessary files in the CPU built-in memory.
Clear the CPU built-in memory by selecting "Clear" to "Operation Setting at CPU Built-in Memory Boot" in
the memory card parameters, and execute the boot function.