16 Machine Parameters
#2089
bsax_pl
Set the base axis of superimposition control using the 2nd axis name (axname2).
A numerical character cannot be set as the 1st character.
(Note) This parameter is enabled only when "#1280 ext16/bit7 Control axis superimposition command meth-
od" is set to "1".
---Setting range---
A to Z and 1 to 9 (Two digits)
(Setting will be cleared when "0" is set)
#2090
plrapid
Set the rapid traverse rate for superimposition control.
(Equivalent to "#2001 rapid Rapid traverse rate".)
---Setting range---
0 to 1000000(mm/min)
#2091
plclamp
Set the cutting feed clamp speed for superimposition control.
(Equivalent to "#2002 clamp Cutting feed clamp speed".)
---Setting range---
0 to 1000000(mm/min)
#2092
plG0tL
Set the G0 time constant (linear) for superimposition control.
(Equivalent to "#2004 G0tL G0 time constant (linear)".)
---Setting range---
0 to 4000(ms)
#2093
plG0t1
Set the G0 time constant (primary delay) for superimposition control.
(Equivalent to "#2005 G0t1 G0 time constant (primary delay".)
---Setting range---
0 to 5000(ms)
#2094
plG1tL
Set the G1 time constant (linear) for superimposition control.
(Equivalent to "#2007 G1tL G1 time constant (linear)".)
---Setting range---
0 to 4000(ms)
#2095
plG1t1
Set the G1 time constant (primary delay) for superimposition control.
(Equivalent to "#2008 G1t1 G1 time constant (primary delay)".)
---Setting range---
0 to 5000(ms)
#2096
crncsp
Set the minimum clamp speed for corner deceleration in the high-accuracy control mode. Normally set "0".
(Note) This parameter is invalid during SSS control.
---Setting range---
0 to 1000000 (mm/min)
IB-1501279-H
Superimposition control base axis
Rapid traverse rate for super-imposition control
Cutting feed clamp speed for super-imposition control
G0 time constant for superimposition control (linear)
G0 time constant for superimposition control (primary
delay)
G1 time constant for superimposition control (linear)
G1 time constant for superimposition control (primary
delay)
Minimum corner deceleration speed