M800/M80/E80/C80 Series Alarm/Parameter Manual
2 Stop Codes (T)
T01
In absolute position alarm
Details
A start signal was input during an absolute position detection alarm.
Remedy
Clear the absolute position detection alarm, and then input the start signal.
T01
In abs posn initial setting
Details
A start signal was input during zero point initialization in the absolute position detection system.
Remedy
Complete zero point initialization before inputting the start signal.
T01
In manual measurement
Details
Automatic start is disabled because manual measurement is in execution.
Remedy
Execute automatic start after the manual measurement is completed.
T01
Sub part sys I mode is active
Details
Cycle start signal was input for the part system that has applied Sub-part system I operation mode.
Remedy
Use Sub-part system I operation mode signal to switch whether to start the operation as Sub-part system
control or to execute cycle start as Main-part system.
T01
Cycle st. prohibit(safe speed)
Details
An automatic operation was started in one of the following machining modes during the safe speed clamp:
thread cutting, synchronous tapping, cross machining, superimposition control, tool center point control or SSS
control.
Remedy
Turn ON the safely-limited speed monitoring request signal and press the cycle start button.
Close the door and press the cycle start button.
T01
Cycle start prohibit (AL Z83)
Details
Cycle start is disabled while the system alarm Z83 (NC started during SP rotation) is occurring.
Remedy
Turn OFF the power and make sure that the spindle is at a standstill. And then turn the power ON again.
T01
In interference check alarm
Details
Cycle start cannot be operated because interference check alarm is in progress.
Remedy
Release the interference check alarm before operating the cycle start.
T01
Cycle st forbid (measuring err)
Details
Cycle start cannot be executed for other part systems during measurement of rotation center error or workpiece
installation error.
Remedy
Execute cycle start for one part system that is ready for measurement.
Cancel measurement when error measurement is not executed.