M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#11087

Meas basic point

Select how to specify the measurement reference point coordinates for manual tool length measurement I (L
system).
0: Use the machine zero as the reference point
1: Use the coordinates of #2015 tlml- as the reference point (the same operation as when #1282 bit2 = 0
for M7)
2: Use the workpiece coordinate system offset (modal) as the reference point (the same operation as when
#1282 bit2 = 1 for M7)
#11091

PLC counter valid

[M8]
Select whether to have the monitor screen show a PLC axis position counter.
0: Monitor screen does not show a PLC axis position counter.
1: Depending on the selected counter type, monitor screen is able to show.
(PR)
#11094

GX Restriction

[M8]
Select whether to block the connection from GX Developer.
0: Allow the connection
1: Block the connection
#11100

3D_MChk_ToolAlm

[M8]
Select whether the 3D machine interference check outputs an alarm or not when the tool is not mounted.
0: Not output an alarm when the tool check is disabled or the tool is not mounted.
1: Output an alarm when the tool check is disabled or the tool is not mounted.
(PR)
#11101-
Monitr menu(MTB)1-30
11130
Designate the destination menu Nos. to move monitor screen's main menus.
-1
: Menu not displayed
0
: No change
1 to 30: Destination menu Nos.
(PR)
#11151-
Setup menu(MTB) 1-30
11180
Designate the destination menu Nos. to move setup screen's main menus.
-1
: Menu not displayed
0
: No change
1 to 30: Destination menu Nos.
(PR)
#11201-
Edit menu(MTB) 1-30
11230
Designate the destination menu Nos. to move edit screen's main menus.
-1
: Menu not displayed
0
: No change
1 to 30: Destination menu Nos.
(PR)
#11251-
Diagn menu(MTB)1-30
11280
Designate the destination menu Nos. to move diagn screen's main menus.
-1
: Not display the menu
0
: No change
1 to 30: Destination menu No.
IB-1501279-H
Tool length measurement I reference point (for L sys-
tem only)
Enable PLC axis counter
Inhibiting GX Developer connection
Alarm when tool interference check is disabled
Monitor main menu (MTB) 1 to 30
Setup main menu (MTB) 1 to 30
Edit main menu (MTB) 1 to 30
Diagn main menu (MTB) 1 to 30
464