POINT
POINT
POINT
(1) Example of [Detail setting].
For examples of [Detail setting], refer to the
following.
8.4 PLC Side Setting
(2) Communication interface setting by Utility
The communication interface setting can be
changed on the Utility's [Communication Settings]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
GT
User's Manual
(3) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
8.3.3

Ethernet setting

Item
Description
The host is displayed.
Host
(The host is indicated with an
asterisk (*).))
Set the network No. of the
N/W No.
connected Ethernet module.
(Default: blank)
Set the station No. of the
*4
connected Ethernet module.
PLC No.
(Default: blank)
Set the type of the connected
*1
Ethernet module.
Type
(Default: QJ71E71/LJ71E71)
Set the IP address of the
IP Address
connected Ethernet module.
(Default: blank)
Set the port No. of the
*2
connected Ethernet module.
Port No.
(Default: 5001)
*3
UDP
Communication
*1
Select one of the following [Controller Type].
• Built-in Ethernet port (hereafter CPU): RCPU, RnMTCPU,
RnPCPU
• C Controller module (MELSEC iQ-R Series): RnCCPU
• Built-in Ethernet port (MELSEC iQ-F Series): FX5CPU
• Connection to Built-in Ethernet port: QnUD(P)V/QnUDEH,
QCPU, Q170MCPU, Q170MSCPU(-S1), Q173D(S)CPU/
Q172D(S)CPU
• C Controller module (Q Series): QnD(H)CCPU
• Connection to Built-in Ethernet port LCPU: LCPU
• Ethernet module (NZ2GF-ETB): NZ2GF-ETB
• Q17nNCCPU: Q17nNC
• The RnENCPU varies in choice of Controller Type by a
port name.
Port CPU P1 : RCPU
Port P1
: RJ71EN71
Port P2
: Not applicable to the Ethernet
connection.
• Ethernet module (MELSEC iQ-R Series): RJ71EN71
• Ethernet module (Q, L Series): QJ71E71/LJ71E71
• Ethernet module (QnA Series): AJ71QE71
• Ethernet module (A Series): AJ71QE71
• Ethernet module (FX Series): FX
• Built-in Ethernet port FXCPU: FX
For the applicable Ethernet module, refer to the following.
8.2 System Configuration
8. ETHERNET CONNECTION
8.3 GOT Side Settings
1
2
Range
3
-
1 to 239
1 to 64
4
RCPU,
RnCCPU,
FX5CPU,
QnUD(P)V/QnUDEH,
QnD(H)CCPU,
LCPU,
Q17nNC,
RJ71EN71,
QJ71E71/LJ71E71,
AJ71QE71,
5
AJ71E71,
FX,
NZ2GF-ETB
0.0.0.0 to
255.255.255.255
1024 to 65534
6
UDP, TCP
7
8
8 - 19