(2) When connecting the GOT and PLC in Ethernet communication
Step 1.
Click the Connection Destination view
the Navigation window of MT Setting/Monitoring tool for C Controller module.
Step 2.
The [Transfer Setup] is displayed.
Step 3.
Set the [Transfer Setup]:
PLC side I/F : GOT
Other station : No specification
Step 4.
Double-click [GOT] of the CPU side I/F to display [CPU side I/F Detailed Setting of GOT].
Step 5.
Mark the [via GOT(Ethernet) transparent mode] checkbox on the [CPU side I/F Detailed Setting of GOT]
screen.
Step 6.
By clicking [Set], the [GOT (Ethernet) Transparent Setting] is displayed.
Here, set the C Controller module (Q Series) (Q24DHCCPU-V), which is firstly connected via a GOT.
[Connection Destination]
22.7 Personal Computer Side Setting
[(Connection target data name)] in
22 - 147