22.8.3

When using MT Developer, MT Works2

■1. When exiting MT Developer, MT Works2
For 45 seconds after MT Developer, MT Works2 has been exited, the GOT continues monitoring at the same speed as
when the FA transparent function is working.
■2. When PLC write is failed while using the FA transparent function
The execution of PLC write using the FA transparent function may be failed due to some reasons such as cable
disconnection.
When this occurs, re-execute the PLC write from the same personal computer, or reset the motion controller CPU.
■3. When a cable disconnection has occurred
When the cable between the GOT and the motion CPU is disconnected, it takes time until a timeout error occurs in MT
Developer, MT Works2.
22.8.4
When using MR Configurator, MR Configurator2
■1. Unavailable functions and restrictions
For the use via the motion controller, there are unavailable functions and restrictions.
For details on the restrictions, refer to the help screen of MR Configurator.
■2. Monitor speed of GOT
Since the FA transparent function is used via the motion CPU, the monitor speed of GOT is slow.
22.8.5
When using FR Configurator
■1. GOT monitoring when using FA transparent function
When FA transparent function is used, GOT suspends monitoring on channels supporting FA transparent function.
■2. When using the oscilloscope function specified sampling
Since the monitoring of the inverter data may be not performed at the specified sampling intervals depending on the
settings of oscilloscope function, adjust the communication setting, a sampling interval, etc.
■3. PU mode operation command source selection
On the setting of PU mode operation command source selection (Pr:551) of the inverter, specify the terminal (1:RS-485
terminals, 2:PU connected) connected to GOT.
22 - 162
22.8 Precautions
POINT
POINT
POINT
Cancelling the suspended GOT monitoring immediately
To cancel the suspended (45 seconds) GOT monitoring immediate30ly after FA transparent is
executed, input "1" to device GS457.Then GOT resumes monitoring.
If FA transparent is resumed even if "1" is already input to device GS457, an error will occur on
FR Configurator.
For the details of the device, refer to the following manual.
GT Designer3 Version
Screen Design Manual