R&S SGT100A User Manual page 499

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
[:SOURce]:POWer:POWer <Amplitude>
Sets the level at the RF output connector.
This value does not consider a specified offset. The command
LEVel][:IMMediate][:AMPLitude]
means the level containing offset.
Parameters:
<Amplitude>
Example:
Manual operation:
[:SOURce]:POWer:PEP?
Queries the RF signal peak envelope power.
Return values:
<PEP>
Usage:
[:SOURce]:POWer:SCHaracteristic <Characteristic>
Selects the characteristic for the level setting.
Parameters:
<Characteristic>
Manual operation:
[:SOURce]:POWer[:LEVel][:IMMediate][:AMPLitude] <Amplitude>
Sets the RF level at the RF output connector of the instrument.
User Manual 1176.8674.02 ─ 07
sets the level of the "Level" display, that
float
Range:
-20 to 25
Increment: 0.01
*RST:
-10
POW:POW 15
sets the RF level at output to 15 dBm.
See
"Level/Level Offset"
float
Query only
AUTO | UNINterrupted | CVSWr | USER | MONotone
UNINterrupted
uninterrupted level setting
CVSWr
constant-VSWR
MONotone
strictly monotone
*RST:
AUTO
See
"Setting Characteristic"
Remote Control Commands
SOURce Subsystem
[:SOURce]:POWer[:
on page 60