R&S
SGT100A
Return values:
<SNumber>
Example:
Usage:
Manual operation:
:SENSe<ch>[:POWer]:SOURce <Source>
Determines the signal to be measured.
Note: When measuring the RF signal, the sensor considers the corresponding correc-
tion factor at that frequency, and uses the level setting of the instrument as reference
level.
Parameters:
<Source>
Example:
Manual operation:
:SENSe<ch>[:POWer]:STATus[:DEVice]?
Queries if a sensor is connected to the instrument.
Return values:
<Status>
Example:
Usage:
Manual operation:
:SENSe<ch>[:POWer]:SVERsion?
Queries the software version of the connected R&S NRP power sensor.
Return values:
<SVersion>
Example:
Usage:
User Manual 1176.8674.02 ─ 07
SENSe, READ, INITiate and SLISt Subsystems
string
SENS1:SNUM?
Queries the serial number.
Query only
See
" Serial Number "
A | USER | RF
*RST:
A
SENS1:SOUR RF
The sensor measures the power of the RF signal
See
" Source "
on page 226
0 | 1 | OFF | ON
*RST:
0
SENS1:STAT?
Response: 1
A sensor is connected
Query only
See
" State "
on page 226
string
SENS1:POW:SVER?
Queries the software version of the power sensor.
Query only
Remote Control Commands
on page 225
337