SGT100A
Example
How to create multi segment waveform file
1. Select "New List" to create an empty list.
2. Use the "Append" function to add two or more waveform files.
3. Adjust the "Level", "Clock" and "Segment Marker" settings.
4. Select the "Output File" and enter a filename.
5. Select "Save List" to save the configuration.
6. Select "Create" or "Create and Load" to create and save the multi segment wave-
form.
General Settings
► To access this dialog, select "SGMA-GUI > Instrument Name > Baseband > ARB >
Multi Segment.. > General".
This dialog comprises the settings for managing files and lists as well as the possi-
bility to add a comment.
New List
Calls the "Create Multi Segment Waveform List" dialog to enter the name of the new
file.
A new configuration table is created.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SELect
Load List
Opens the file menu to select the configuration file to be edited.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CATalog?
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SELect