Reference Oscillator - R&S SGT100A User Manual

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
"Ext"
Remote command:
[:SOURce]:LOSCillator:SOURce
REF/LO Output
Determines the signal provided at the output connector REF/LO OUT.
"OFF"
"LO"
"REF"
Remote command:
:CONNector:REFLo:OUTPut

7.7.5 Reference Oscillator

The R&S SGT is equipped with an internal TXCO reference oscillator. If equipped with
the additional HW option R&S SGT-B1, an OXCO can be used as an internal reference
frequency source for the synthesizer. Moreover, an external reference signal source
can be connected to the REF/LO IN connector of the instrument.
► To access this dialog, select "SGMA-GUI > Instrument Name > RF > Reference
Oscillator".
User Manual 1176.8674.02 ─ 07
The signal fed-in at the REF/LO IN input connector is used as signal
source.
An icon in the block diagram indicates that an external LO source is
used.
Note: The local oscillator input/output requires the additional software
option R&S SGT-K90.
on page 341
No signal is provided.
The signal of the local oscillator (LO) is available at the REF/LO OUT
connector.
The signal of the reference oscillator is available at the REF/LO OUT
connector.
on page 314
Signal Generator Settings