Const I/Q Test Signal - R&S SGT100A User Manual

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:RECTangle:SAMPles
Amplitude
Enters the digital amplitude of the rectangular wave. The abbreviation FS stands for full
scale.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:RECTangle:AMPLitude
Offset DC
Enters a DC component.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:RECTangle:OFFSet
Generate Signal File
Generates a signal and saves it to a file.
The "File Select" window opens automatically and the signal can be stored as a wave-
form file.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:SINE:CREate:NAMed
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:RECTangle:CREate:NAMed
on page 366
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:CIQ:CREate:NAMed
Generate Signal RAM
Generates a signal and uses it as output straight away.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:SINE:CREate
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:RECTangle:CREate
[:SOURce<hw>]:BB:ARBitrary:TSIGnal:CIQ:CREate
7.1.2.7

Const I/Q Test Signal

This dialog provides settings for configuration of a continuous test signal with constant
IQ. The I and Q values for each path are adjustable but constant.
Converted to analog, the signal is output directly at the I and Q connectors of the
instrument.
User Manual 1176.8674.02 ─ 07
Signal Generator Settings
Baseband
on page 367
on page 366
on page 367
on page 366
on page 366
on page 366
on page 366
on page 366
108