Source:bb:progress Subsystem General Commands - R&S SGT100A User Manual

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
[:SOURce]:BB:IMPairment:IQOutput<ch>:IQRatio[:MAGNitude] <IqRatio>
Sets the ratio of I modulation to Q modulation (amplification imbalance) of the corre-
sponding digital I/Q channel. The input may be either in dB or %. The resolution is
0.001 dB, an input in percent is rounded to the closest valid value in dB. A query
returns the value in dB.
Parameters:
<IqRatio>
Manual operation:
[:SOURce]:BB:IMPairment:IQOutput<ch>:SKEW <Skew>
Sets a delay between the Q vector and the I vector of the corresponding stream.
Parameters:
<Skew>
Manual operation:
[:SOURce]:BB:IMPairment:IQOutput<ch>:LEAKage:I <I>
[:SOURce]:BB:IMPairment:IQOutput<ch>:LEAKage:Q <Q>
Determines the leakage amplitude of the I or Q-signal component of the corresponding
stream.
Parameters:
<Q>
Manual operation:

11.14.7 SOURce:BB:PROGress Subsystem General Commands

In the R&S SGT, some calculation processes take longer time. While operating the
instrument manually, you can observe the status of an initiated process by the busy
indicator. The following commands fulfill the same task in the remote control operation.
User Manual 1176.8674.02 ─ 07
float
Range:
-1 to 1
Increment: 1E-4
*RST:
0
See
"Gain Imbalance"
float
Range:
-500E-9 to 500E-9
Increment: 1E-12
*RST:
0
See
"Skew "
on page 141
float
Range:
-10 to 10
Increment: 0.01
*RST:
0
See
"I/Q Offset"
on page 140
Remote Control Commands
SOURce Subsystem
on page 140
412

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents