A positive I/Q skew means that the Q vector delays relative to the I vector and vice
versa.
Parameters:
<Skew>
Example:
Manual operation:
[:SOURce<hw>]:BB:IMPairment:STATe <State>
The command activates (ON) and deactivates (OFF) the three impairment or correc-
tion values LEAKage, QUADrature and IQRatio for the digital baseband signal prior to
input into the I/Q modulator.
Parameters:
<State>
Example:
Manual operation:
[:SOURce<hw>]:BB:IMPairment:OPTimization:MODE <Mode>
This command sets the optimization mode.
Parameters:
<Mode>
Example:
Manual operation:
[:SOURce<hw>]:BB:IMPairment:OPTimization:STATe <State>
Activates and deactivates internal compensation of signal distortions by the I/Q modu-
lator.
User Manual 1176.8674.02 ─ 07
float
Range:
-500E-9 to 500E-9
Increment: 1E-12
*RST:
0
BB:IMP:SKEW 410.0E-9
sets the I/Q skew.
See
"Skew "
on page 141
0 | 1 | OFF | ON
*RST:
0
BB:IMP:STAT OFF
deactivates digital impairment.
See
"State"
on page 139
FAST | QHIGh
FAST
Optimization is reached by compensation for I/Q skew.
QHIGh
Optimization is reached by compensation for I/Q skew and fre-
quency response correction.
*RST:
FAST
BB:IMP:OPT:MODE FAST
sets the optimization mode Fast.
See
"Optimization Mode"
Remote Control Commands
SOURce Subsystem
on page 137
410