R&S Sgma-Gui Settings - R&S SGT100A User Manual

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
:INSTruments:ACTive:STATe ON,OFF,OFF
// Activates the first
// i.e. the instruments with symbolic names SGS-100006
// ******************************************************************
// Export the configuration into a mapping file
// ******************************************************************
:INSTruments:MAPPing:FILE 'd:\mapping_files\mapping.map'
// ******************************************************************
// Enable exclusive access for the selected instrument
// ******************************************************************
:INSTruments:EACCess:STATe?
// Response: 0,0,0
:INSTruments:EACCess:STATe ON,0FF, 0FF
// Locks the first instrument
6.6.2 R&S SGMA-GUI Settings
This section comprises the SCPI commands provided to remote control the R&S
SGMA-GUI.
:INSTruments:ACTive[:STATe]
:INSTruments:ACTive[:STATe] <State>
Enables/disables the instrument for the R&S SGMA-GUI. The main panel of this soft-
ware displays only activated instruments.
Parameters:
<State>
Example:
User Manual 1176.8674.02 ─ 07
Understanding the R&S SGMA-GUI Software
instruments in the list,
.......................................................................................... 70
..................................................................................................... 71
.......................................................................................71
............................................................................................ 71
........................................................................................................ 71
....................................................................................... 72
........................................................................................... 72
...........................................................................................72
..............................................................................................72
........................................................................................................ 73
......................................................................................... 73
....................................................................................................... 73
.........................................................................................................73
List of BOOL-values
<StateInstr#1>,<StateInstr#2>,...
0, 1, ON, OFF
See
Chapter 6.6.1, "Configuring Instruments in the R&S SGMA-
GUI",
on page 68.
Remote Control of the R&S SGMA-GUI
70

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents