Each log file contains the measured value (2 readings when you work with peak sen-
sors), the sensor type, and the measurement time (timestamp). Logged data is not
overwritten. When a new measurement is started, the collected logging data is appen-
ded in the log file.
Check the used disc space regularly and remove log files to maintain storage capacity.
Note: The logging function is intended for measurements with long time intervals. It is
suitable source for data reconstructions if the connection to the sensor was interrupted.
Remote command:
:SENSe<ch>[:POWer]:LOGGing:STATe

7.7.9 Pulse Modulation

This section explains the pulse modulation settings of the R&S SGT.
To configure and perform a pulse modulation, you need to select the modulation signal
source and provide the corresponding settings.
Modulation signal sources
The R&S SGT provides the following signal sources for the signal modulation:
Internal: A high-performance pulse generator, that allows you to generate either
single or double pulse signals
Externally supplied signal: the instrument expects the pulse modulation signals
at the TRIG connector.
Pulse modulation signal waveforms
The high-performance pulse generator enables you to generate single or double pulse
signals.
Figure 7-27: Pulse generator - single pulse mode
1 = Pulse period
2 = Pulse width
3 = Pulse delay