[:Source<Hw>]:Bb:arbitrary:mcarrier:preset; [:Source<Hw>]:Bb:arbitrary:mcarrier:samples; [:Source<Hw>]:Bb:arbitrary:mcarrier:setting:catalog - R&S SGT100A User Manual

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Example:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:PRESet
Sets all ARB multi carrier parameters to their default values.
Example:
Usage:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SAMPles?
The command queries the resulting file size. The file size is returned in samples.
Return values:
<Samples>
Example:
Usage:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:CATalog?
Queries the available settings files in the specified default directory. The settings files
are used to set the ARB multi carrier submenu. Only files with the file extension
*.arb_multcarr will be listed.
Return values:
<Catalog>
Example:
Usage:
User Manual 1176.8674.02 ─ 07
MMEM:CDIR "/var/user/waveform"
sets the default directory.
BB:ARB:MCAR:OFIL 'mcar1_2'
defines the file name mcar1_2.wv for the multi carrier wave-
form file
See
"Output File"
on page 100
SOURce1:BB:ARB:MCARrier:PRESet
Event
See
"Set to Default"
on page 95
integer
Range:
0 to INT_MAX
*RST:
0
BB:ARB:MCAR:SAMP?
queries the file size of the currently calculated multi carrier
waveform.
Query only
See
"File Size"
on page 100
string
MMEM:CDIR '/var/user/waveform'
sets the default directory
BB:ARB:MCAR:SETT:CAT?
reads out all the settings files in the default directory.
Response: mcar1, mcar2
the directory contains the configuration files
mcar1.arb_multcarr and mcar2.arb_multcarr.
Query only
Remote Control Commands
SOURce Subsystem
381

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents