Source:iq:output:envelope Commands - R&S SGT100A User Manual

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Example:
Manual operation:
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:MODE <Mode>
Determines the mode for setting the output parameters.
Parameters:
<Mode>
Example:
Manual operation:
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:OFFSet:I <I>
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:OFFSet:Q <Q>
Sets an offset between the inverting and non-inverting input of the differential analog
I/Q output signal.
Parameters:
<Q>
Example:
Manual operation:

11.14.13 SOURce:IQ:OUTPut:ENVelope Commands

The following remote control commands require software option R&S SGT-K540.
User Manual 1176.8674.02 ─ 07
:IQ:OUTP:TYPE DIFF
:IQ:OUTP:LEV 1.5 V
outputs the differential I/Q signal with 1.5 V power.
See
"I/Q Level Vp EMF"
FIXed | VARiable
FIXed
locks the I/Q output settings
VARiable
unlocks the settings
*RST:
FIXed
SOUR:IQ:OUTP:MODE VAR
SOUR:IQ:OUTP:ANAL:POW:LEV 2V
See
"Mode"
on page 144
float
Range:
-0.3 to 0.3
Increment: 1E-4
*RST:
0
:SOURce1:IQ:OUTPut:ANALog:TYPE DIFF
:SOURce1:IQ:OUTPut:ANALog:OFFSet:I 0.05 V
:SOURce1:IQ:OUTPut:ANALog:OFFSet:Q 0.05 V
See
"Offset (EMF)"
on page 145
Remote Control Commands