ABB IRB 6650S - 200/3.0 Product Manual page 374

Articulated robot
Table of Contents

Advertisement

5 Calibration information
5.5. Updating revolution counters
Continued
372
Action
2. Tap the mechanical unit in question.
A screen is displayed: tap Rev. Counters.
en0400000771
3. Tap Update Revolution Counters....
A dialog box is displayed, warning that updating the revolution counters may change
programmed robot positions:
Tap Yes to update the revolution counters.
Tap No to cancel updating the revolution counters.
Tapping Yes displays the axis selection window.
4. Select the axis to have its revolution counter updated by:
Ticking in the box to the left
Tapping Select all to update all axes.
Then tap Update.
5. A dialog box is displayed, warning that the updating operation cannot be undone:
Tap Update to proceed with updating the revolution counters.
Tap Cancel to cancel updating the revolution counters.
Tapping Update updates the ticked revolution counters and removes the tick from the
list of axes.
6.
CAUTION!
If a revolution counter is incorrectly updated, it will cause incorrect robot positioning,
which in turn may cause damage or injury!
Check the calibration position very carefully after each update.
See section
Checking the calibration position on page
373.
3HAC020993-001 Revision: G

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 6650s - 125/3.5Irb 6650s - 90/3.9

Table of Contents