ABB IRB 6650S - 200/3.0 Product Manual page 178

Articulated robot
Table of Contents

Advertisement

3 Maintenance
3.4.8. Replacement of SMB battery
Continued
Removal, battery
The procedure below details how to remove the SMB battery.
176
Action
1. Move the robot to its calibration position.
2.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
3.
esd
WARNING!
The unit is sensitive to ESD, before handling the
unit please observe the safety information in
section
WARNING - The unit is sensitive to ESD!
on page 40
4. Remove the SMB battery cover by unscrewing its
attachment screws.
5. Pull out the battery and disconnect the battery
cable.
6. Remove the SMB battery.
Battery includes protection circuits. Replace it
only with the specified spare part or with an ABB
approved eqvivalent.
Note
This is done in order to facilitate the
updating of the revolution counter.
Shown in the figure
Location of SMB
battery on page
175.
Shown in the figure
Location of SMB
battery on page
175.
Shown in the figure
Location of SMB
battery on page
175.
Continues on next page
3HAC020993-001 Revision: G