ABB IRB 6650S - 200/3.0 Product Manual page 281

Articulated robot
Table of Contents

Advertisement

Refitting, brake release unit
The procedure below details how to refit the brake release unit.
3HAC020993-001 Revision: G
Action
7. Remove the brake release unit from the
bracket by removing the four attachment
screws.
Action
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the
air pressure to motors and SMB.
2.
esd
WARNING!
The unit is sensitive to ESD, before handling
the unit please observe the safety information
in section
WARNING - The unit is sensitive to
ESD! on page 40
3. Fasten the brake release unit on the bracket
with the attachment screws.
Make sure the unit is positioned as straight as
possible on the bracket! The push buttons can
otherwise get jammed when the SMB cover is
refitted.
4. Connect the connectors X8, X9 and X10 to the
brake release unit.
4.5.2. Replacement of brake release unit
Note/Illustration
Note/Illustration
Shown in the figure
Location of brake
release unit on page
Art. no. is specified in
equipment on page
277!
xx0200000129
A: Connector X8
B: Connector X9
C: Connector X10
D: Push buttons
Continues on next page