Field Service Ver. 2.1 Feb. 2012
16. MECHANICAL ADJUSTMENT
16.1 Mechanical adjustment of the scanner section
16.1.1
Adjustment of the scanner motor belt
This adjustment must be made in the following case:
• The scanner motor assy has been removed.
• The scanner drive cables have been rewound.
[2]
[1]
[4]
[2]
[2]
[1]
A0EDF3C511DA
[4]
[3]
[4]
[2]
A0EDF2C258DA
16. MECHANICAL ADJUSTMENT
1. Temporarily secure the scanner
motor assy [1] with three screws [2].
2. With the scanner drive gear set
screw [1] located on the right-hand
side as shown on the left, slide the
scanner motor assy [2] to the left and
check that it is returned to the origi-
nal position by the tension of the
spring [3].
Perform this step three times.
3. Tighten the three screws [4] to fix the
scanner motor assy into position.
531