5. MECHANICAL ADJUSTMENT
5.
MECHANICAL ADJUSTMENT
5.1
Adjusting the paper reference position
NOTE
• Make this adjustment after any of the following procedures has been performed.
When the PH unit has been replaced.
When the image on the print is offset in the main scan direction.
When adjustment in the following screen does not resolve a problem.
[Service Mode] - [Machine] - [Printer Area] - [Centering].
[1]
[1]
5. Perform another test print and check the reference deviation.
20
A
4348fs3509c0
[2]
A0XWF3C506DA
[2]
A0XWF3C507DA
Field Service Ver. 1.0 Jul. 2009
1. Measure the width of printed refer-
ence line A.
Specification: 3.0 mm
2. Slide out the drawer [1] and unload
paper from it.
3. Loosen two screws [2] at the center
of the paper lifting plate.
4. Watching the graduations [1] pro-
vided in the drawer, move the edge
guide [2] in the rear.
• If width A is greater than the specified
value, move the edge guide toward the
front.
• If width A is smaller than the specified
value, move the edge guide toward the
rear.
±
1.0 mm