Field Service Ver. 2.1 Feb. 2012
10.6.32

User Authentication/Account Track-Authentication Device Settings

• The function can be displayed only when the authentication device 2 is set to Set by
[Service Mode] → [Billing Setting] → [Management Function Choice]
A. General Settings
(1) Use
• Specifies a device used for user authentication.
Card Authentication : Select the IC card type and operation settings.
Bio Authentication
(2) Procedure
• Select either one of the authentication devices and press the corresponding key to go to
the individual operation setting screen.
• The screen displays the authentication device that is selected in [Service Mode] → [Bill-
ing Setting] → [Management Function Choice] → [Authentication Device 2].
When [Card 1] is selected as the authentication device, select the card type from among
[FeliCa], [TypeA], [SSFC], [FCF], and [FCF (Campus)] and make the operation settings.
If [FeliCa+Type A], [SSFC+Type A], [FCF+Type A], or [FCF (Campus)+Type A] is
selected, both the FeliCa and Type A cards can be used in this machine at the same
time.
When [Card 2] is selected as authentication device, the authentication device name will
be displayed differently depending on the type of installed loadable device driver.
• If SSFC (Shared Security Formats Cooperation) is selected in Card Authentication, set
[Company Code], [Company Identification Code], [Area No.], [Building No.], [Floor No.],
[Room No.], and [Security Level].
• If LEGIC (PID) is selected in Card Authentication, perform the access setting (STAMP
input) for LEGIC (PID).
• If MIFARE (PID) is selected in Card Authentication, perform the MIFARE key setting.
(3)
How to set the card information when using SSFC card.
2.1
• When using SSFC card for user authentication, get the following information from the
administrator.
And it is necessary to convert the information into the value for the control panel.
Item
Room Number
Floor Number
Building Number
Area Number
Security Level
Company
Identification Code
(CL Code) *2
Company Code *3
*1: Enter the value as a decimal number format.
*2: The character length of the company code is 10 bytes.
*3: Use alphabetical upper case/lower case characters and numeric characters for Com-
pany code. When the company code is not set, this space will be left blank.
: Select the beep and operation settings.
Card Authentication
Necessary information
Sampled-data
(hexadecimal number)
37 (decimal number)
15 (decimal number)
50 (decimal number)
85 (decimal number)
2 (decimal number)
06BGLQVX17
(ASCII code)
CompanyA
(ASCII code)
Bio Authentication
Sampled-data
00 25
00 0F
00 32
00 55
00 02
30 36 42 47 4C 51
56 58 31 37
-
10. UTILITY
Setting value
on the control panel
37 *1
15 *1
50 *1
85 *1
2 *1
30 36 42 47 4C 51
56 58 31 37
CompanyA