19. TROUBLE CODE
19.5.82
C3921: Fusing sensor wire breaks detection (Heating side)
19.5.83
C3923: Fusing sensor wire breaks detection (Pressurizing side)
Fusing unit
Step
1
Check the fusing unit for correct installation
(whether it is secured in position).
2
Check the open/close operation of the right
door.
3
Check the fusing unit, DCPU and PRCB for
proper connection and correct or change
as necessary.
4
Change fusing unit
5
Change PRCB
6
Change DCPU
19.5.84
C4101: Polygon motor rotation trouble
PH unit
Step
1
Check the connector between PH unit-
PHREYB CN6 for proper connection and
correct as necessary.
2
Check the connector between PHREYB
CN3-PRCB CN26 for proper connection
and correct as necessary.
3
Change PH unit
4
PHREYB ICP1 conduction check
5
Change PHREYB
6
Change PRCB
654
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 2.1 Feb. 2012
DC power supply (DCPU)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
—
—
—
—
—
—
PH relay board (PHREYB)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
—
—
—
—
—
—
Location (Electri-
cal component)
—
—
—
—
—
—
Location (Electri-
cal component)
—
—
—
—
—
—