19. TROUBLE CODE
19.5.97
C6704: Image input time out
MFP board (MFPB)
Step
Select [Service Mode] → [State Confirma-
1
tion] → [Memory/HDD Adj.] → [Memory
Bus Check] → [Scanner→Memory], and
conduct the memory bus function.
2
Check the connectors between scanner
section and MFPB for proper connection
and correct as necessary.
3
Change MFPB
4
Change CCDB
19.5.98
C6751: CCD clamp/gain adjustment failure
Exposure unit
Step
1
Check the connector between CCDB PJ2-
MFPB PJ01 for proper connection and cor-
rect as necessary.
2
Check for possible extraneous light and
correct as necessary.
3
Clean the lens, mirrors, CCD surface, and
shading sheet if dirty
4
Correct reflective mirror of the scanner if
faulty, or change scanner.
5
Change CCDB
6
Change MFPB
660
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 2.1 Feb. 2012
CCD board (CCDB)
WIRING DIAGRAM
Control signal
—
—
—
—
CCD board (CCDB)
MFP board (MFPB)
WIRING DIAGRAM
Control signal
—
—
—
—
—
—
Location (Electri-
cal component)
—
—
—
—
Location (Electri-
cal component)
—
—
—
—
—
—