3. OTHER MAINTENANCE ITEM
OK
NG
5. Reinstall the above parts following the removal steps in reverse.
3.3.6
Glass cleaning roller unit
1. Open the reverse automatic document feeder.
[2]
[1]
[2]
[1]
20
NOTE
• When carrying the reverse auto-
matic document feeder, be sure to
hold onto the specified positions.
The feeder main body can be dis-
torted if held at inappropriate posi-
tions.
A01HF2C507DB
2. Remove the C-clip [1] and the bush-
A0HUF2C012DA
3. Shift the bushing [1] and remove the
A0HUF2C013DA
Field Service Ver. 1.0 Jul. 2009
ing [2].
belt [2].