Field Service Ver. 2.1 Feb. 2012
5.6

Cleaning procedure

NOTE
• The alcohol described in the cleaning procedure represents the ethanol isopropyl
alcohol.
5.6.1

Transfer belt unit

1. Remove the transfer belt unit.
See P.34
[1]
5.6.2

PH window

1. Open the front door.
2. Remove the waste toner box.
See P.37
[1]
2. Using a cleaning pad, wipe the trans-
NOTE
• Do not wipe out with water.
• Do not wipe out with any solvents.
A0EDF2C232DA
3. Clean the PH window by putting the
NOTE
• Clean every PH window of Y,M,C,K.
A0EDF2C513DA
5. OTHER MAINTENANCE ITEMS
fer belt [1].
PH window cleaning jig back and
forth a couple times.
139