10. UTILITY
L. User Paper Settings
• It will be displayed only when the following setting is set to "Level 2."
[Service Mode] → [Enhanced Security] → [Administrator Feature Level]
(1) Use
• To set and register individual user paper that includes different basic weight and transfer
output fine adjustment data.
• To register a paper type that is suitable for customer's intended use and use environ-
ment.
• The feature available from [Service Mode] → [System 2] → [User Paper Settings] is
extended to Administrator. However, the fusing temperature setting is not possible in
Administrator Settings.
• The user paper registration keys and corresponding paper types are as follows:
User Paper 1, 2 : Plain paper
User Paper 3
User Paper 4
User Paper 5
(2) Procedure
1. Call the Administrator Settings to the screen.
2. Touch [System Settings] → [Expert Adjustment] → [Forward] → [User Paper Settings].
3. Select the desired key from [User Paper 1] to [User Paper 5] to register user paper.
4. Select [Basic Weight] and enter a value with the [+]/ [-] key.
5. Select one from the following; [Media Front - Color], [Media Front - Black], [Media Back-
Color], or [Media Back - Black]. Enter a 2nd transfer output value with the [+]/[-] key.
Setting range: -7 to +8 (1 step: 1 increment or decrement)
6. Load the tray with A4S or 8
7. Touch [Test Pattern Output]. Specify a paper feed tray and select either 1st side or 2nd
side.
8. Press the Start key and check the image of the output test pattern. If the image is not
acceptable, adjust the settings, output and check a test pattern again.
(3) Test pattern in user paper settings
• The printable test pattern for user paper settings is provided to ease determining the
most appropriate 2nd transfer output value used when customizing user paper.
• This test pattern changes output voltage as shown below based on the standard voltage
A (voltage determined by the 2nd image transfer auto transfer voltage control) on a sheet
of paper.
248
: Thick 1
: Thick 2
: Thick 3
/
x 11S paper.
1
2
Field Service Ver. 2.1 Feb. 2012
A +600 V
A +400 V
A +200 V
A 0 V
A -200 V
A -400 V
A: standard voltage
A -600 V
A0P0F3C539DA