19. TROUBLE CODE
19.5.144 CC213: User registration error/card information setting error
2.1
MFP board (MFPB)
Step
1
Check the USB cable for proper connection
and correct as necessary.
2
Turn OFF the main power switch, wait for
10 sec. or more, and turn ON the main
power switch.
3
Reset the authentication settings. (card
type, IC card advanced settings, and etc.)
4
Re-register the user authentication infor-
mation.
19.5.145 CC214: User information deletion error
2.1
MFP board (MFPB)
Step
1
Check the USB cable for proper connection
and correct as necessary.
2
Turn OFF the main power switch, wait for
10 sec. or more, and turn ON the main
power switch.
19.5.146 CC216: Acquisition failure of the number of trials/Initialize error of number
2.1
of authentication
MFP board (MFPB)
Step
1
Check the USB cable for proper connection
and correct as necessary.
2
Turn OFF the main power switch, wait for
10 sec. or more, and turn ON the main
power switch.
3
Reset the number of authentication trials.
672
2.1
Relevant parts
Action
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 2.1 Feb. 2012
Authentication device
WIRING DIAGRAM
Control signal
—
—
—
—
Authentication device
WIRING DIAGRAM
Control signal
—
—
Authentication device
WIRING DIAGRAM
Control signal
—
—
—
Location (Electri-
cal component)
—
—
—
—
Location (Electri-
cal component)
—
—
Location (Electri-
cal component)
—
—
—