6. Open the right door.
[1]
[2]
[1]
[1]
[1]
A0EDF2C094DA
A0EDF2C027DA
[2]
[3]
[1]
A0EDF2C095DA
5. OTHER MAINTENANCE ITEMS
5. To mark the position where the right
door assy is installed, draw two
guide lines on the scales [1] indi-
cated on the machine frame.
7. Remove the screw [1], and remove
the connector cover [2].
8. Disconnect three connectors [1].
9. Remove the screw [2], and remove
the ground terminal [3].