Field Service Ver. 2.1 Feb. 2012
10. To reinstall, reverse the order of removal.
2
12. Execute [Skew adjustment] and [Skew adjustment reset] after selecting [Service Mode]
→ [Machine] → [Skew adjustment].
9. Remove the PH unit [1].
A0EDF2C082DA
11. Select [Skew adjustment] after
A0EDF2C529DB
5. OTHER MAINTENANCE ITEMS
selecting [Service Mode] →
[Machine] → [Skew adjustment], and
input the adjustment value that is put
on the side of the replaced PH unit.
See P.386
71
2