Field Service Ver. 1.0 Jul. 2009
6. Reinstall the above parts following the removal steps in reverse.
3.3.7
Horizontal transport unit
1. Remove the finisher from the main body.
See P.14
[1]
[1]
4. Reinstall the above parts following the removal steps in reverse.
A0HRF2C509DA
A0HRF2C500DA
[2]
A0HRF2C501DA
3. OTHER MAINTENANCE ITEM
CAUTION
• When transporting the finisher,
make sure to push it to the direc-
tion as shown in the illustration. (to
prevent turnover during transporta-
tion).
2. Remove the relay connector [1].
3. Remove two screws [1], and remove
the horizontal transport unit [2].