19. TROUBLE CODE
19.5.181 CE002: Message and method parameter failure
MFP board (MFPB)
Step
1
Turn OFF the main power switch and turn it
ON again, and conduct the following set-
ting.
[Service Mode] → [System 1] → [Initializa-
tion] → [Data Clear].
See P.433
2
Format hard disk.
3
Change hard disk.
4
Change MFPB.
19.5.182 CEEE1: MFP board malfunction
MFP board (MFPB)
Step
1
Check the connectors on MFPB for proper
connection and correct as necessary.
2
Change MFPB
19.5.183 CEEE2: Scanner section malfunction
Exposure unit
Step
1
Correct the connector connection between
CCDB and REYB/SCAN if faulty.
2
Change REYB/SCAN
3
Change CCDB
680
Relevant parts
Action
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 2.1 Feb. 2012
Hard disk
WIRING DIAGRAM
Control signal
—
—
—
—
WIRING DIAGRAM
Control signal
—
—
CCD board (CCDB)
Scanner relay board (REYB/SCAN)
WIRING DIAGRAM
Control signal
—
—
—
Location (Electri-
cal component)
—
—
—
—
Location (Electri-
cal component)
—
—
Location (Electri-
cal component)
—
—
—