10. UTILITY
M. Error Code Display Setting
(1) Use
• To set whether or not to display an error code when a network-related error occurs.
• To help to identify the cause of network error by displaying an error code.
(2) Procedure
• The default setting is OFF.
10.6.52

Network Settings-IEEE802.1X Authentication Settings

A. Use
• To set whether or not to use IEEE802.1X authentication.
• To display IEEE802.1X authentication status.
• To initialize IEEE802.1X authentication settings.
NOTE
• IEEE802.1X authentication settings are made with PageScope Web Connection.
B. Procedure
• The default setting is OFF.
<Auth. Status>
• Displays present IEEE802.1X authentication status.
<Reset Job Settings>
• Returns all IEEE802.1X authentication settings to initial values.
<Certificate Verification Level Settings>
• Sets a certificate verification method for server certificate verification.
Expiration Date
CN
Chain
10.6.53

Network Settings-Web Browser Setting

• It will be displayed only when the optional i-Option (LK-101 v2 or LK-103 v2) is activated.
A. Use
• To set whether to use the web browser function.
B. Procedure
• The default setting is Enable.
314
ON
ON
: Select whether to check that the server certificate is
within the validity period.
: Select whether to check that the CN of the server certif-
icate matches the server address.
: Select whether to check that the server certificate chain
(certification path) is correct.
The chain is validated by referencing the external certif-
icates managed on this machine.
"Enable"
Field Service Ver. 2.1 Feb. 2012
"OFF"
"OFF"
Invalid