Field Service Ver. 1.0 Jul. 2009
MAINTENANCE
2.
PERIODICAL MAINTENANCE PROCEDURE
2.1
Paper feed section
2.1.1
Replacing the separation roller
A. Periodically replaced parts/cycle
• Separation roller assy: Every 300,000 feed
NOTE
• Replace the separation roller assy, feed roller and pick-up roller at the same time.
B. Procedure
1. Remove the right door.
See P.12
[2]
[1]
2. PERIODICAL MAINTENANCE PROCEDURE
[1]
A0XWF2C001DA
[2]
[1]
A093F2C500DA
2. Remove two springs [1].
3. Remove the jam clearing cover [2].
4. Remove two screws [1] and remove
the paper separation roller mounting
bracket assy [2].
3