6. Mechanical adjustment
6.
Mechanical adjustment
6.1
Leading edge skew adjustment
NOTE
• This adjustment should be made when image skew occurs.
20
1. Print the test pattern1.
See P.137 of the main body service
manual.
2. Load the chart in the Auto Document
Feeder Unit and make five 1-sided
copies of the chart.
4139F3C557DA
3. Align each copy sample as shown
and check the deviation.
4. If the deviation is outside the speci-
fied range, perform the adjustment
below.
Specification: 0 ± 1.0 mm
4139F3C558DA
5. Loosen the one screw [1] in the back
to the right.
[1]
4139F3C515DA
Field Service Ver. 1.0 Aug. 2007