Field Service Ver. 2.1 Feb. 2012
12.14.6
Original Tray Width
A. Use
• To set the values of maximum (A3 position) and minimum (B6 position) widths on the
document width detection variable resistor.
• When an original misfeed occurs.
• When an original size detection error occurs.
• When the document width detection variable resistor has been replaced.
• When the EEPROM has been replaced.
B. Procedure
1. Call the Service Mode to the screen.
2. Touch [ADF] → [Original Tray Width].
[1]
4. Touch [Max. Width].
5. Press the Start key.
6. OK is displayed when the adjustment has been completed.
8. Touch [Min. Width].
9. Press the Start key.
10. OK is displayed when the adjustment has been completed.
11. Touch [END].
12. Touch [Exit] on the Service Mode screen.
13. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON.
NOTE
If the result is NG:
• Possible causes includes failure of the document width detection variable resistor,
wrong wiring to the volume and failure of the DFCB.
A0HTF2C037DA
[1]
A0HTF2C038DA
12. SERVICE MODE
3. Widen the width across the edge
guides [1] by sliding them to the "A3"
position.
7. Narrow the width across the edge
guides [1] by sliding them to the "B6"
position.
493