Field Service Ver. 2.1 Feb. 2012
12.8.7
Install Date
A. Use
• To register the date the main body was installed.
• Upon setup.
B. Procedure
1. Call the Service Mode on the screen.
2. Select the key as follows.
[System 1] → [Install Date].
3. Enter the date (Year 4 digit → Month 2 digit → date 2 digit) from the 10-key pad.
4. Touch [Entry] to set the date of installation.
12.8.8
Initialization-Clear All Data
A. Use
• To initialize the setting data.
• For details on items to be cleared, see "CONTENTS TO BE CLEARED BY RESET
FUNCTION."
See P.530
NOTE
• When removing or installing the hard disk after registering the data below, be sure
to clear the data.
Referring data: One-touch registration, user authentication/account track.
B. Procedure
1. Call the Service Mode to the screen.
2. Select the key as follows.
[System 1] → [Initialization] → [Clear All Data].
3. Press the Start key.
4. When [OK] is displayed, turn off the main power switch and turn it on again more than
10 seconds after.
12.8.9
Initialization-Clear Individual Data
• Clear Individual Data enables you to select and clear multiple items at a time.
A. Copy Program Data
(1) Use
• To clear data registered as copy program.
• Use this feature to clear all copy program data at a time.
(2) Procedure
1. Call the Service Mode on the screen.
2. Select the key as follows.
[System 1] → [Initialization] → [Copy Program Data].
3. Press the Start key.
4. When [OK] is displayed, turn off the main power switch and turn it on again more than
10 seconds after.
12. SERVICE MODE
433