Field Service Ver. 2.1 Feb. 2012
(7) Sensor monitor 7
Symbol
Panel display
Scanner
PS201
Home Sensor
Org. Detecting Sensor
RS201
Original Cover
PS202
20 Degree
PS204
Original Size
Detection 1
PS205
Original Size
Detection 2
⎯
Original Size
Detection 3
⎯
Original Size
Detection 4
⎯
Original Size
Detection 5
⎯
Original Size
Detection 6
⎯
Original Size
Detection 7
⎯
Original Size
Detection 8
*1: Detection is made at 20 degrees and 15 degrees of open/close angle when mounting
the original cover OC-509 and the reverse automatic document feeder DF-617 respec-
tively.
Part/signal name
Scanner home sensor
Original cover sensor
Angle sensor
Original size detection 1 sensor
Original size detection 2 sensor
Not used
Not used
Not used
Not used
Not used
Not used
12. SERVICE MODE
Operation characteris-
tics/panel display
1
0
At home
Out of
home
Lowered
Raised
Less than
20 degree
20 degree
or more *1
*1
Original
Original not
loaded, not
loaded
mounted
Original
Original not
loaded, not
loaded
mounted
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
473