4.10 Registration Section; Cleaning Of The Timing Roller; 4.11 Fusing Section; Replacing The Fusing Unit - Konica Minolta bizhub C360 Service Manual

All-in-one color laser mfp
Hide thumbs Also See for bizhub C360:
Table of Contents

Advertisement

Field Service Ver. 2.1 Feb. 2012

4.10 Registration section

4.10.1

Cleaning of the timing roller

A. Periodically cleaning parts/cycle
• Timing roller: Every 60,000 counts (upon each call)
B. Procedure
1. Open the right door and the regist unit.
[1]

4.11 Fusing section

4.11.1

Replacing the fusing unit

• The temperature gets high in the vicinity of the fusing unit. You may get
burned when you come into contact with the area. Before replacement
operations, make sure that more than 20 minutes have elapsed since the
main and sub power switches were turned off.
A. Periodically replacing parts/cycle
• Fusing unit: Every 523,000 counts
B. Procedure
1. Remove the rear right cover.
See P.56
4. PERIODICAL MAINTENANCE PROCEDURE
2. Using a cleaning pad with alcohol,
A0EDF2C035DA
CAUTION
2. Disconnect two connectors [1].
[1]
A0EDF2C007DA
wipe the timing roller [1] clean of dirt.
47