2. PERIODICAL MAINTENANCE PROCEDURE
8
[1]
A01HF2C005DA
[1]
A01HF2C006DA
Field Service Ver. 1.0 Jul. 2009
5. While opening up the holder [1],
remove the shaft.
NOTE
• Opening the holder too much can
break the holder.
6. Remove the separation roller [1]
from the shaft.
NOTE
• Be careful not to lose the pin.