19. TROUBLE CODE
19.5.6
C0209: LCT elevator motor failure
Elevator motor (M5)
Elevator motor pulse sensor (PS10)
Step
1
Check the connector between M5-REYB
CN2 for proper connection and correct as
necessary.
2
Check the connector between PS10-REYB
CN2 for proper connection and correct as
necessary.
3
Check the connector of each motor for
proper drive coupling, and correct as nec-
essary.
4
PS10 I/O check, sensor check
5
M5 operation check
6
Change REYB
7
Change PCCB
19.5.7
C0210: LCT lift failure
Lift-up upper limit sensor (PS4)
Lift-up lower limit sensor (PS13)
Elevator motor pulse sensor (PS10)
Step
1
Check the connector between PS4-PCCB
CN5 for proper connection and correct as
necessary.
2
Check the connector between PS13-PCCB
CN2 for proper connection and correct as
necessary.
3
Check the connector between PS10-PCCB
CN2 for proper connection and correct as
necessary.
4
Check the connector between PS7-PCCB
CN2 for proper connection and correct as
necessary.
5
PS4 I/O check, sensor check
6
PS13 I/O check, sensor check
7
PS10 I/O check, sensor check
8
PS7 I/O check, sensor check
9
Change PCCB
620
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 2.1 Feb. 2012
Relay board (REYB)
PC control board (PCCB)
WIRING DIAGRAM
Control signal
—
—
—
REYB CN2<A>-5 (ON)
REYB CN2<B>-6 to 7
—
—
Lower limit over run sensor (PS7)
PC control board (PCCB)
WIRING DIAGRAM
Control signal
—
—
—
—
PCCB CN5-12 (ON)
REYB CN2<A>-9 (ON)
REYB CN2<A>-5 (ON)
REYB CN2<A>-2 (ON)
—
Location (Electri-
cal component)
—
—
—
PC-408 K-5
PC-408 K-6
—
—
Location (Electri-
cal component)
—
—
—
—
PC-408 G-8
PC-408 K-3 to 4
PC-408 K-5
PC-408 K-6
—