Konica Minolta bizhub C360 Service Manual page 642

All-in-one color laser mfp
Hide thumbs Also See for bizhub C360:
Table of Contents

Advertisement

Field Service Ver. 2.1 Feb. 2012
Code
Item
C2411 Developing unit (C) new
article release
C2412 Developing unit (M) new
article release
C2413 Developing unit (Y) new
article release
C2414 Developing unit (K) new
article release
C2551 Abnormally low toner
density detected cyan
TCR sensor
C2552 Abnormally high toner
density detected cyan
TCR sensor
C2553 Abnormally low toner
density detected magenta
TCR sensor
C2554 Abnormally high toner
density detected magenta
TCR sensor
C2555 Abnormally low toner
density detected yellow
TCR sensor
C2556 Abnormally high toner
density detected yellow
TCR sensor
C2557 Abnormally low toner
density detected black
TCR sensor
C2558 Abnormally high toner
density detected black
TCR sensor
Detection timing
• The status with the new unit is not cleared
after the new developing unit is set.
• When sampling data is determined in TC
ratio calculation control, TCR sensor output
is higher than a predetermined value for a
predetermined number of times in a row
even though there is toner in the sub hop-
per.
• TC ratio in the developing unit which is
determined by toner replenishing amount
control mechanism, is a predetermined
value or more for a given number of times
consecutively.
• When sampling data is determined in TC
ratio calculation control, TCR sensor output
is higher than a predetermined value for a
predetermined number of times in a row
even though there is toner in the sub hop-
per.
• TC ratio in the developing unit, which is
determined by toner replenishing amount
control mechanism, is a predetermined
value or more for a given number of times
consecutively.
• When sampling data is determined in TC
ratio calculation control, TCR sensor output
is higher than a predetermined value for a
predetermined number of times in a row
even though there is toner in the sub hop-
per.
• TC ratio in the developing unit, which is
determined by toner replenishing amount
control mechanism, is a predetermined
value or more for a given number of times
consecutively.
• When sampling data is determined in TC
ratio calculation control, TCR sensor output
is higher than a predetermined value for a
predetermined number of times in a row
even though there is toner in the sub hop-
per.
• TC ratio in the developing unit, which is
determined by toner replenishing amount
control mechanism, is a predetermined
value or more for a given number of times
consecutively.
19. TROUBLE CODE
Trouble iso-
Rank
lation
B
B
B
B
B
B
B
B
B
B
B
B
587