16. Mechanical adjustment
16. Mechanical adjustment
16.1 Mechanical adjustment of the scanner section
16.1.1
Scanner Position Adjustment
Make this adjustment after any of the following procedures has been performed:
• After the Scanner Drive Cables have been replaced.
• When the Scanner has been removed.
1. Remove the IR Upper Left Cover.
49
2. Remove the Front Holding Bracket.
49
3. Remove the Original Glass.
49
4. Remove the Exposure Unit.
78
212
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500
5. Move the Mirror Unit to the position
shown on the left.
• Distance of part A from the IR left side
surface: 68.5 mm
4040F2C691DA
6. Wind the cables on the Exposure
Unit.
7. 7. Mount the Exposure Unit at the
location shown on the left.
• Distance of the right side surface of
the Exposure Unit from the IR left side
surface: 138 mm
4040F2C692DA
Field Service Ver. 1.0 Aug. 2005