19. TROUBLE CODE
Code
Item
C0210 LCT lift failure
C0211 Manual feed up/down
abnormality
C0212 LCT ejection failure
C0213 LCT shift gate malfunction • The division board position sensor (PS14)
580
Detection timing
• The lift-up upper limit sensor (PS4) is not
blocked even after the set period of time has
elapsed after the paper lift-up operation
began.
• The lift-up upper limit sensor (PS4) is not
blocked even after the set pulse is detected
by the elevator motor pulse sensor (PS10)
after the paper lift-up operation began.
• The lift-up lower sensor (PS13) is not
unblocked even after the set pulse is
detected by the elevator motor pulse sensor
(PS10) after the paper lift-up operation
began.
• The lift-up upper limit sensor (PS4) is not
blocked even after the set period of time has
elapsed after the paper lift-up operating.
• The lift-up lower limit sensor (PS13) is not
blocked even after the set period of time has
elapsed after the paper lift-down operation
began.
• The lift-up lower limit sensor (PS13) is not
blocked even after the set pulse is detected
by the elevator motor pulse sensor (PS10)
after the paper lift-down operation began.
• The lift-up upper limit sensor (PS4) is not
unblocked even after the set pulse is
detected by the elevator motor pulse sensor
(PS10) after the paper lift-down operation
began.
• The lower limit over run sensor (PS7) is
blocked while the paper lift-down operating.
• Paper does not unblock the manual lift-up
position sensor even after the transport
motor rotates for a given period of time after
the position is switched from stand by posi-
tion at lift-up plate to the feed position.
• The manual lift-up position sensor is not
blocked even after the transport motor
rotates for a given period of time after the
position is switched from stand by position
at lift-up plate to the feed position.
• The drawer cannot be determined to be out
of position even after the set period of time
has elapsed after the tray lock solenoid
(SD1) is energized after the lowering opera-
tion is finished.
cannot be set to L even after the set period
of time has elapsed after the operation of
the division board position motor (M3)
began with the division board position sen-
sor (PS14) set to L.